Factory Made Hot China Products 16mm aluminium XLPE Insulated Power Cable
Product Description Of XLPE Insulated Power Cable
Product standard:
GB/T12706.1-2008
Application:
This product is suitable for power transmission and distribution line of rated voltage (U0/U) 0.6/1.0KV line.
Technical Parameter:
When the cable is running normally, the Maximum temperature of conductor is 90℃; and is 250 ℃ when the short circuit (Max. last 5s) happens.
The ambient temperature of installation shall not lower than 0 degrees.
Minimum bending radius is 12 D (“D” refers to cable diameter)
Single Core Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current |
In the air | Buried in soil |
Cu | AL | Cu | AL | Cu | AL | Cu | AL |
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
1*1.5 | 0.7 | 1.5 | 6 | 53 | 53 | ≤12.1 | ≤12.1 | 3.5 | 26 | 26 | 33 | 32 |
1*2.5 | 0.7 | 1.5 | 6 | 68 | | ≤7.41 | 3.5 | 34 | 43 |
1*4 | 0.7 | 1.5 | 7 | 87 | 64 | ≤4.61 | ≤7.41 | 3.5 | 44 | 35 | 56 | 42 |
1*6 | 0.7 | 1.5 | 7 | 110 | 73 | ≤3.08 | ≤4.61 | 3.5 | 56 | 45 | 70 | 54 |
Two Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current |
In the air | Buried in soil |
Cu | AL | Cu | AL | Cu | AL | Cu | AL |
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
2*2.5 | 0.7 | 1.8 | 11.8 | 151 | 118 | ≤7.41 | ≤12.1 | 3.5 | 26 | 20 | 35 | 27 |
2*4 | 0.7 | 1.8 | 12.7 | 198 | 146 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
2*6 | 0.7 | 1.8 | 13.7 | 250 | 173 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
2*10 | 0.7 | 1.8 | 16.3 | 374 | 245 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Three Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current |
In the air | Buried in soil |
Cu | AL | Cu | AL | Cu | AL | Cu | AL |
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
3×1.5 | 0.7 | 1.5 | 10 | 145 | - | ≤12.1 | - | 3.5 | 20 | - | 27 | - |
3×1.6 | 0.7 | 1.5 | 11 | 185 | 140 | ≤7.41 | ≤12.1 | 3.5 | 26 | 20 | 35 | 27 |
3×4 | 0.7 | 1.5 | 12 | 250 | 175 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
3×6 | 0.7 | 1.5 | 13 | 320 | 210 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
3×10 | 0.7 | 1.5 | 15 | 450 | 260 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Four Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current |
In the air | Buried in soil |
Cu | AL | Cu | AL | Cu | AL | Cu | AL |
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
4×4 | 0.7 | 1.5 | 13 | 253 | 155 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
4×6 | 0.7 | 1.5 | 14 | 337 | 184 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
4×10 | 0.7 | 1.5 | 16 | 501 | 258 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Three Cores+One Core Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current |
In the air | Buried in soil |
Cu | AL | Cu | AL | Cu | AL | Cu | AL |
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
3×4+1×2.5 | 0.7 | 1.5 | 13 | 236 | 147 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
3×6+1×4 | 0.7 | 1.5 | 14 | 316 | 187 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
3×10+1×6 | 0.7 | 1.5 | 16 | 461 | 234 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Three Cores+Two Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current |
In the air | Buried in soil |
Cu | AL | Cu | AL | Cu | AL | Cu | AL |
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
3×4+2×2.5 | 0.7 | 1.5 | 13.9 | 309 | 202 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
3×6+2×4 | 0.7 | 1.5 | 15.3 | 413 | 219 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
3×10+2×6 | 0.7 | 1.5 | 18.2 | 603 | 338 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Four Cores+One Core Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current |
In the air | Buried in soil |
Cu | AL | Cu | AL | Cu | AL | Cu | AL |
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
4×4+1×2.5 | 0.7 | 1.5 | 14.5 | 331 | 214 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
4×6+1×4 | 0.7 | 1.5 | 15.9 | 435 | 259 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
4×10+1×6 | 0.7 | 1.5 | 18.9 | 649 | 359 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Five Cores Cable
Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current |
In the air | Buried in soil |
Cu | AL | Cu | AL | Cu | AL | Cu | AL |
mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
5×4 | 0.7 | 1.5 | 14.5 | 349 | 223 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
5×6 | 0.7 | 1.5 | 15.8 | 460 | 271 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
5×10 | 0.7 | 1.5 | 19.3 | 699 | 384 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Product Picture Of XLPE Insulated Power Cable